The recovery of SF6 gas charging and discharging device standard parameters
Type
Refrigerated liquefied, air-cooled, pushing moving type
Working environment temperature
-10 -40
Inflation
The initial pressure (Pa)
133
The final pressure (Pa)
0.7
Volume of 1 cubic meters required time (h/m3)
0.2
The ultimate vacuum (Pa)
10
Vacuum holding from 133 Pa after 24 hour rise value (Pa)
400
Years of leakage rate
1%
After the recovery of SF6 gas purity
Water (PPM/V)
60
Oil (PPM/W)
10
Liquefaction
Refrigerated liquefied (or high pressure liquefied)
Vaporization method
Electric heating
Dry filter regeneration
Vacuum heating activation and regeneration
Power Supply
Three-phase four wire 3 φ 380V
The noise of dB (A)
75
Equipment weight (Kg)
1000
 
The recovery of SF6 gas charging and discharging device specification
 
Serial number
Model
Container volume (L)
SF6 reserves (Kg)
1
LH-12Q/4/40
250
40 (vapor)
2
LH-12Y/4/250
250
250 (liquid)
3
LH-14Y/15/250
250
250 (liquid)
4
LH-14Y/15/400
400
400 (liquid)
5
LH-14Y10/15/400
400
400 (liquid)
6
LH-18Y/15/600
600
600 (liquid)
7
LH-18Y10/18/600
600
600 (liquid)
 
SF6 gas pumping vacuum device specification
Serial number
Model
Remarks
1
ZY/LC-05B
ULVAC native vacuum pump
2
ZY/LC-2B
Import the monoblock pump, digital vacuum gauge
3
ZY/LC-4B
The monoblock pump
4
ZY/LC-4
The monoblock pump
5
ZY/LC-12 (ZY/LC-11)
LEYBOLE monoblock pump
6
ZY/LC-15
Belt pump
7
ZY/LC-15Z
2XZ-15D monoblock pump
8
ZY/LC-18
LEYBOLE monoblock pump
9
ZY/LC-18D
LEYBOLE monoblock pump
10
ZY/LC-25
The monoblock pump
11
ZY/LC-70
Roots pump
12
ZY/LC-70L (with LEYBOLD monoblock pump)
Roots pump
13
ZY/LC-100
European origin
14
ZY/LC-100D
All parts are imported
15
ZY/LC-160
European origin
16
ZY/LC-200
European origin
17
ZY/LC-300
European origin
 
top